Extraction with powder coating

There is always at least zone 22 in the powder coating area. Powder deposits in dangerous quantities (layer thicknesses ≥ 1 mm) can lead to fire hazards and in the event of whirling up also to explosion hazards. In order to prevent these dangers, the cabins must be cleaned regularly and the deposits removed. It must be ensured that:

  • The extraction units to be used are explosion-protected, at least for Zone 22
  • The powder used does not fall below the minimum permissible ignition energy
  • Highly efficient filter technology is used, ideally with automatic filter cleaning

Professional extraction technology from EVO-PRODUCTS is ideally suited for this application. Powerful suction power, highest quality, robust construction and best filter technology guarantee the safe extraction of materials and dusts from these applications.

For this application, please select only EX-protected versions (Type 22).:

Power: 1.5 kW
Voltage: 230 volts
Container: 25 liters
Continuous operation 24/7
EX-protection
Dust class M / H / Type22

Power: 1.5 kW
Voltage: 230 volts
Container: 35 liters
Continuous operation 24/7
EX-protection
Dust Classes: M / H / Type22

Power: 1.5 to 2.2 kW
Voltage: 230/400 volts
Container: 35 liters
Continuous operation 24/7
EX-protection
Dust Classes: M / H / Asbestos / Type22

Power: 2.2 to 3.0 kW
Voltage: 400 volts
Container: 60 liters
Continuous operation 24/7
EX-protection
Dust Classes: M / H / Type22

Power: 2.2 to 5.5 kW
Voltage: 400 volts
Container: 60 liters
Continuous operation 24/7
EX-protection
Dust Classes: M / H / Type22

Power: 4.0 to 7.5 kW
Voltage: 400 volts
Container volume: 100 liters
Continuous operation 24/7
EX-protection
Dust Classes: M / H / Type22

Power: 1.5 to 7.5 kW
Voltage: 230/400 volts
Container: 35 to 100 liters
Continuous operation 24/7
EX-protection
Dust class: M / H / Asbestos / Type22

Power: 1.5 to 7.5 kW
Voltage: 230/400 volts
Disposal: Longopac
Continuous operation 24/7
EX-protection
Dust Classes: M / H / Asbestos / Type22

Compressed air ejectors: 2
Consumption: 56m³/h (at 4 bar flow pressure)
Operating pressure: 6-10 bar
Container: 60 litres
Continuous operation 24/7
EX-protection for
Zones 1 + 2 and zones 21 + 22
Dust classes: M / H

Central extraction system
Cartridge filter device
Power: 1.1 to 3.3 kW
Voltage: 230 or 400 volts
Continuous operation 24/7
Air volume: 450 to 1,360 m³ / h
Dust Classes M / H / Type22 (EX)

Central extraction system
Cartridge filter device
Power: 1.5 to 2.2 kW
Voltage: 400 volts
Continuous operation 24/7
Air volume: 2,050 to 2,500 m³ / h
Dust Classes M / H / Type22 (EX))

Central extraction system
Cartridge filter device
Power: 3.0 to 11.0 kW
Voltage: 400 volts
Continuous operation 24/7
Air volume: 3,800 to 9,000 m³ / h
Dust Classes M / H / Type22 (EX)